01 · Manufacturing
Environmental test chambers,
engineered around your standard.
26 chamber families spanning temperature, thermal shock, climatic simulation, altitude, HAST, battery, and solar qualification. Every unit designed to the client's test method — IEC, MIL-STD, ASTM, ISO, RTCA DO-160 — and commissioned to it.
01
Temperature & Climate
8 chamber types
Hot & Cold (Steady State)
IEC 60068-2-1/-2
−73 → +300 °C
Hot & Cold (Cycling)
IEC 60068-2-14
−73 → +300 °C · programmed
Temp-Humidity (Steady)
IEC 60068-2-30
−40 → +180 °C · 10–98 %RH
Temp-Humidity (Cycling)
IEC 60068-2-38
Combined T/H cyclic
Humidity (Steady State)
IEC 60068-2-78
10 → 98 %RH
Low Humidity (Steady)
ASTM D1149
down to 5 %RH
Fast-Rate Temperature Cycling
MIL-STD-810
up to 15 °C/min
Hot Oven
IEC 60068-2-2
up to +300 °C
02
Thermal Shock
4 chamber types
Two-Zone Air-to-Air Shock
MIL-STD-883G 1010
−65 ⇄ +200 °C · <10 s transfer
Three-Zone Thermal Shock
IEC 60068-2-14 Na
Ambient + 2 extremes
Liquid-to-Liquid Shock
JESD22-A106
Dual liquid bath
Humidity Shock
IEC 60068-2-30
Rapid RH transition
03
Environmental Simulation
7 chamber types
Salt Spray / Fog Chamber
ASTM B117 · ISO 9227
5 %NaCl · 35 °C
Dust Ingress
IEC 60529 · MIL-STD-810 510
IP5X / IP6X
Rain Test
IEC 60529
IPX1 – IPX9K
Drip / Fine-Mist / Immersion
IEC 60529
IPX1 – IPX8
Altitude / Vacuum
MIL-STD-810 500
up to 50 km · 5 mbar
Ozone Climate
ASTM D1149 · ISO 1431
25 → 2000 pphm
Mould Growth
IEC 60068-2-10
29 °C · 95 %RH · fungal
04
Specialised & Advanced
6 chamber types
HAST — Highly Accelerated Stress
JESD22-A110
110–130 °C · 85 %RH
Walk-In Climatic Chamber
MIL-STD-810
Custom volume · up to 12 m
Battery Test Chamber
IEC 62660 · UN 38.3
Cell & pack thermal
Solar PV Qualification
IEC 61215 / 61730
IEC 61215 · IEC 61730
Component Burn-In
MIL-STD-883
Accelerated life
Custom-Built System
Standard-agnostic
Bespoke engineering
Custom Engineering
Every chamber begins as a specification.
Standard datasheets are a starting point. Working volumes, ramp rates, uniformity tolerances, controller architecture, and safety instrumentation are all set against your specific test profile.
- Working volumes from 50 L benchtop to 100+ m³ walk-in
- Ramp rates to 15 °C/min · uniformity ±0.5 °C
- Redundant refrigeration and PLC-based safety interlocks
- Data acquisition, remote monitoring and audit-grade logging
- Feed-through ports, cable glands, window options, floor loading
- Commissioning, IQ/OQ documentation, calibration and AMC support
Response Standard